Estimate Cooling Length for Wire Turbulence
- hydro data without cooling
| frame 11 |
| |
| frame 12 |
| |
| frame 14 |
| |
| Wire Temperature at x=1.15 |
| |
| internal energy at x=1.1 |
| |
| Vy at x=1.1 | ; |
| frame | Ave rho (number density) | Wire Temp | Ave e | Max Vy |
| 11 | 0.051 | 2.5E-4 | 5081 | 0.05 |
- Equations in the code
Cooling time t_cooling=e/(N*lambda(T)) for DM cooling
AnalyticCoolingStrength=rho2 * A_alpha*T0A_beta*ScaleCool for Analytic
A_alpha=alpha_cooling*4.76e-20*&! (ergs*cm3/s/K.5)
(3d0/16d0*Xmu*muH*amu/Boltzmann*(vy_cooling)2)(power)
A_beta=beta_cooling
- Cooling Length Estimate '
| alpha_cooling | 3.30E-18 |
| beta_cooling | 0 |
| vy_cooling | 0.05 |
| A_alpha | 4.18E-43 |
| A_beta | 0 |
| nScale | 4.8345E+23 |
| pScale | 1 |
| TimeScale | 1 |
| scaleCool | 2.3373E+47 |
| Cooling Strength | 2.5378E+02 |
| Cooling Time | 2.0021E+01 |
| Cooling Length | 1.0011E+00 |